Operation CHARM: Car repair manuals for everyone.

Sensor Adjustment





INSPECTION AND ADJUSTMENT


LASER BEAM AIMING ADJUSTMENT : Sensor Adjustment


CAUTION:
Never view ICC sensor unit body window directly during laser beam aiming adjustment.

NOTE:
Complete all necessary steps for laser beam adjustment until the CONSULT-III indicates "COMPLETED". If the procedure does not complete, the ICC system is inoperable.
1.SET CONSULT-III TO THE LASER BEAM AIMING ADJUSTMENT MODE
1. Connect CONSULT-III and select "Work Support" of "ICC".
2. Select "LASER BEAM ADJUST".
3. Touch "START".

NOTE:
If the adjustment screen does not appear on CONSULT-III 10 sec. after touching "LASER BEAM ADJUST" screen, the following causes may be considered:
- Target is not set accurately.
- There is not enough space beside the target.
- Deformation of vehicle or inappropriate installation of sensor. Sensor may be installed out of the adjustable range.
- The area is not suitable for the adjustment work.
- ICC sensor is not clean.
- GO TO 2
2.LASER BEAM AIMING CONFIRMATION
After the CONSULT-III displays "ADJUST THE VERTICAL OF LASER BEAM AIMING" turn the vertical adjusting screw until "U/D CORRECT" value is set in the range of �4.

NOTE:





- Turn the screw slowly. The value on the CONSULT-III is slower than the actual movement of the ICC sensor. Wait 2 seconds between each adjustment. Also, during adjustment work, do not block the ICC sensor lens with your hand or body. In that case, there are times when aiming cannot be conducted correctly.
- Turning the screw clockwise raises the ICC sensor and counterclockwise lowers the ICC sensor.
- GO TO 3
3.LASER BEAM AIMING CONFIRMATION
1. When "U/D CORRECT" value indicates �4, confirm that the value remains within �4 for at least 2 seconds while nothing is touching the ICC sensor.
2. When "COMPLETED THE VERTICAL AIMING OF LASER BEAM" appears on screen, touch "END".

NOTE:
Be sure that the margin of "U/D CORRECT" is within �4 when the ICC sensor unit is untouched.
3. Confirm that "ADJUSTING AUTOMATIC HORIZONTAL LASER BEAM AIMING" is on screen and wait while the horizontal adjustment is made automatically. (maximum: 10 seconds).
4. Confirm that "NORMALLY COMPLETED" is displayed on CONSULT-III and close the aiming adjustment procedure by touching "END".

NOTE:
Complete all the procedures once "LASER BEAM ADJUST" mode is entered in CONSULT-III. When the procedure is discontinued, the ICC system is inoperable.
- LASER BEAM AIMING ADJUSTMENT END.

CHECK AFTER THE ADJUSTMENT
Test the ICC system by performing the ICC System Running Test. Action Test .