With Automatic Back Door Closer
BUZZER (COMBINATION METER)
Description
Performs operation method guide and warning using buzzer.
Component Function Check
1.CHECK FUNCTION
1. Check the operation using "INSIDE BUZZER" in the Active Test.
2. Touch "TAKE OUT", "KNOB"or "KEY"on screen.
Is the inspection result normal?
Yes - Warning buzzer into combination meter is OK.
No - SEE Diagnosis Procedure.
Diagnosis Procedure
1.CHECK METER BUZZER CIRCUIT
Meter Buzzer Circuit.
Is the inspection result normal?
Yes - GO TO 2.
No - Repair or replace harness.
2.CHECK INTERMITTENT INCIDENT
Intermittent Incident.
- INSPECTION END