Operation CHARM: Car repair manuals for everyone.

Special Repair Requirement





CALIBRATION OF DECEL G SENSOR


Special Repair Requirement


CAUTION:
After removing/replacing the yaw rate/side/decal G sensor or replacing the ABS actuator and electric unit (control unit), the decel G sensor of the ABS actuator and electric unit (control unit) must be calibrated first. Description.
1.PREPARATION BEFORE CALIBRATION PROCEDURE
1. Park the vehicle on a flat road.
2. Adjust pressure in all tires to the specified value. [1][2]Specifications.
- GO TO 2.
2.PERFORM CALIBRATION
With CONSULT-III
1. Turn ignition switch ON.

CAUTION:
Never start the engine.
2. Select "G SENSOR CALIBRATION" in "Work Support" in "TRANSMISSION".
3. Touch "START".

CAUTION:
Never give any motion to the vehicle during the calibration.
Is "completed" displayed?
YES - GO TO 3.
NO - Perform the calibration again.
3.CHECK DTC
With CONSULT-III
1. Turn ignition switch OFF and wait 10 seconds or more.
2. Turn ignition switch ON.
3. Select "Self Diagnostic Results" in "ABS".
Is "C1145" or "C1146" detected?
YES - Testing and Inspection.
NO - Calibration end.