Variable Intake Manifold Solenoid Test
This test is conducted check VIM Solenoid for proper operation.Tech 2 must be used for this test.
Test Procedure:
1. Connect Tech 2 to the vehicle DLC.
2. Ignition SW is "On".
3. Select F3: Miscellaneous Test in the Application Menu.
4. Select F6: Variable Intake Manifold Solenoid Test.
5. Push "On" or "Off" of soft key.
6. Control VIM Solenoid check data list.
7. If data list changes, the VIM Solenoid is normal.