Turn Signals: Description and Operation
Circuit OperationTurn Operation
With the starter switch in ON or START battery voltage is applied to the hazard warning switch from fuse C-3. When the hazard warning switch is in the OFF position, battery voltage is applied to the flasher unit. Its output is pulsing voltage which is directed to either the RIGHT or LEFT position on the turn signal switch and causes the turn lights and turn indicator lights to flash in either direction.
Hazard Operation
Battery voltage is applied to the hazard warning switch at all times from fuse F-3. When the hazard warning switch is in the HAZARD position, battery voltage is applied to the flasher unit. Its output is pulsing voltage which is directed to the hazard warning switch and causes the turn lights and turn indicator lights to flash in both directions.