Turn Signals: Description and Operation
With the starter switch in
ON or
START, battery voltage is applied to the
hazard warning switch from the BACKUP/TURN LIGHT fuse CB-15. When the hazard warning switch is in the
OFF position, battery voltage is applied to the flasher unit. The flasher units output is pulsing voltage which is directed to either the LEFT or RIGHT position on the
turn signal switch and causes the turn lights and turn indicator lights to flash in either direction.