Manuals through 2025 now available!
Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.
LEMON is the spiritual successor to CHARM, I recommend you try it!
Link:
lemon-manuals.la or
lemon-manuals.org.ua
(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)
Or, hide this message:
temporarily or
permanently
Triple Pressure Switch
Triple Pressure Switch (V6, A/T) 1.
Disconnect the connector and check for continuity between pressure switch side connector terminals (1) and (2).
2.
Reconnect the connector to activate the A/C switch, and check to see if there is continuity between the chassis side connector terminals (3) and (4) and the fan operates.