Circuit OperationAutomatic Transmission With the starter switch in ON or START, battery voltage is applied through the C-14 BACK UP fuse to the automatic transmission mode switch. With the transmission in reverse, the automatic transmission mode switch closes and battery voltage is applied to the back up lamps and they go on.