Operation CHARM: Car repair manuals for everyone.

Control Module Failure

PINPOINT TEST G295394p1: DTC B1342; CONTROL MODULE FAILURE
G295394tl: CHECK THE POWER SUPPLY TO THE EPB CONTROL MODULE
1. Disconnect the EPB control module electrical connector, CR502. Measure the voltage between CR50, pin 01 (NW) and GROUND.
^ Is the voltage less than 10 volts?
Yes
REPAIR the circuit between the EPB control module and battery. This circuit includes the battery junction box (fuse 32). CLEAR the DTC. TEST the system for normal operation.
No
GO to Pinpoint Test G295394t2.

G295394t2: CHECK THE GROUND TO THE EPB CONTROL MODULE
1. Measure the resistance between CR50, pin 04 (13) and GROUND.
^ Is the resistance greater than 5 ohms?
Yes
REPAIR the high resistance circuit. CLEAR the DTC. TEST the system for normal operation.
No
Contact dealer technical support for advice on possible EPB control module failure.