Oxygen Sensor: Service and Repair
1. Disconnect connector and remove sensor from manifold.2. Clean threads in manifold,
3. Coat replacement sensor threads with anti-seize compound.
4. Install sensor and torque to 20-25 ft, lbs.
CAUTION: Make sure that wire terminal ends are properly seated in plug before connecting plug.
5. Connect connector. Do not push rubber boot down on sensor more than 1/2 inch above base.
NOTE: Oxygen sensor pigtail wires cannot be spliced or soldered. If broken, replace sensor.