Automatic Shutdown (ASD) Relay
AUTOMATIC SHUTDOWN (ASD) RELAY-PCM OUTPUTFig. 13 PDC Location:
The Automatic Shutdown (ASD) relay is located in the Power Distribution Center (PDC).
The ASD supplies battery voltage to the fuel injectors, ignition coil and both Oxygen (O2S) sensor heating elements. The ground circuit for the coil in the ASD relay is controlled by the Powertrain Control Module (PCM). The PCM operates the relay by switching the ground circuit on and off.