High Pressure Sensor / Switch: Testing and Inspection
Before performing diagnosis of the high pressure cut-off switch, verify that the refrigerant system has the correct refrigerant charge. See Refrigerant System Charge.1. Disconnect and isolate the battery negative cable.
2. Unplug the high pressure cut-off switch wire harness connector from the switch.
3. Check for continuity between the two terminals of the high pressure cut-off switch. There should be continuity. If OK, test and repair the A/C switch sense circuit as required. If not OK, replace the faulty switch.