Hazard Relay Circuit Shorted High
Tests 1 - 3:
SYMPTOM
HAZARD RELAY CIRCUIT SHORTED HIGH
WHEN MONITORED
Ignition in RUN and IOD fuse/connector installed.
SET CONDITION
This code is set if the BCM tries to activate the hazard lamps and excessive current is sinked into the BCM.
POSSIBLE CAUSES
- Combo flasher internal shorted to B(+)
- Hazard switch sense circuit shorted to B(+)
- BCM hazard circuit shorted to voltage