Floor Distribution Ducts Replacement
REMOVALWARNING: ON VEHICLES EQUIPPED WITH AIR-BAGS, DISABLE THE AIRBAG SYSTEM BEFORE ATTEMPTING ANY STEERING WHEEL, STEERING COLUMN, OR INSTRUMENT PANEL COMPONENT DIAGNOSIS OR SERVICE. DISCONNECT AND ISOLATE THE BATTERY NEGATIVE (GROUND) CABLE, THEN WAIT TWO MINUTES FOR THE AIRBAG SYSTEM CAPACITOR TO DISCHARGE BEFORE PERFORMING FURTHER DIAGNOSIS OR SERVICE. THIS IS THE ONLY SURE WAY TO DISABLE THE AIRBAG SYSTEM. FAILURE TO TAKE THE PROPER PRECAUTIONS COULD RESULT IN AN ACCIDENTAL AIRBAG DEPLOYMENT AND POSSIBLE PERSONAL INJURY.
1. Remove the instrument panel from the vehicle. Refer to: Body and Frame, Interior Trim, Dashboard/Instrument Panel, Service and Repair, Instrument Panel Assembly Replacement, Service and Repair
2. Remove the rear floor heat duct from the vehicle.
3. Remove the three screws that secure the floor distribution duct to the bottom of the HVAC housing.
4. Remove the floor distribution duct from the vehicle.
INSTALLATION
1. Position the floor distribution duct onto the bottom of the HVAC housing.
2. Install the three screws that secure the floor distribution duct to the HVAC housing. Tighten the screws to 3.2 Nm (20 in. lbs.).
3. Install the rear floor heat duct.
4. Install the instrument panel. Refer to: Body and Frame, Interior Trim, Dashboard/Instrument Panel, Service and Repair, Instrument Panel Assembly Replacement, Service and Repair