B1446
B1446-VES STOP INPUT BUTTON STUCKWHEN MONITORED
With the ignition on. DVD Player active.
SET CONDITION
The DVD Player detects a closed switch for 60 seconds.
POSSIBLE CAUSES
- DVD player
DIAGNOSTIC TEST
1. VERIFY OPERATION OF THE SWITCH
With the scan tool, erase DTCs.
Press and release the switch three times.
Wait 30 seconds.
With the scan tool, read DTCs.
Q: Is DTC: active?
YES: Replace the DVD Player.
Perform BODY VERIFICATION TEST VER 1. Body Verification Test
NO: Test complete.
Perform BODY VERIFICATION TEST VER 1. Body Verification Test