Body Control System
B210E - BATTERY VOLTAGE HIGHWHEN MONITORED
With the ignition on.
SET CONDITION
Battery voltage greater than 16 volts for more than 15 seconds.
POSSIBLE CAUSES
- Generator field control circuit shorted to battery voltage
- Generator
- PCM
Diagnostic Test
1. CHECK FOR ANY POWERTRAIN CONTROL MODULES DTCS
NOTE:
- Make sure the Battery is in good condition. Using the Midtronics Battery Tester, test the Battery before continuing.
- Inspect the vehicle for after market accessories that may exceed the Generator System output.
- Make sure the generator drive belt is in good operating condition.
- Inspect the fuses in the IPM. If an open fuse is found, use the wire diagram/schematic as a guide, inspect the wiring and connectors for damage.
Turn the ignition on.
With the scan tool, read active PCM DTC's.
Q: Does the scan tool display any active PCM DTC's?
YES: Refer to Computers and Control Systems for the diagnostic test procedure.
NO: Check the above conditions that can cause a high voltage condition. Repair as necessary.