Airbag Lamp Open
AIRBAG LAMP OPEN
For a complete wiring diagram refer to Diagrams/Electrical.
- When Monitored:
With the ignition in the Run/Start position.
- Set Condition:
The Instrument Cluster detects Indicator short/open fault during internal self test.
Diagnostic Test
1. INSTRUMENT CLUSTER
With the scan tool, erase DTCs.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
With the scan tool, read DTCs.
When this code is set, the Instrument Cluster must be replaced.
Yes
- Replace the Instrument Cluster.
- Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
No
- Test Complete.