General Information
P2503 AMP No Battery Charge
General Information
Component Location
General Description
Battery sensor is mounted on the battery (-) terminal. It transmits battery voltage, current, temperature information to PCM. PCM controls the generating output by changing the duty cycle to the generator based on these signals.
DTC Description
PCM sets this code when the battery charging current from battery sensor is too low.
DTC Detecting Condition
Diagnostic Circuit Diagram
Signal Waveform & Data
Fig.1) Normal waveforms of COM, FR terminal of alternator at idle.
Fig.2) Normal waveforms of COM, FR terminal of alternator under high electronic load condition
Fig.3) Normal waveforms of COM, FR terminal of alternator at ig on under connector disconnected condition.
Fig.4) Normal waveforms of COM, FR terminal of alternator at idle under connector disconnected condition.