Air Flow Meter/Sensor: Specifications

Resistance Value
Terminals THA - E2
-4°F (-20°C) 10 - 20k ohms
32°F (0°C) 4 - 7k ohms
68°F (20°C) 2 - 3k ohms
104°F (40°C) 0.9 - 1.3k ohms
140°F (60°C) 0.4 - 0.7k ohms
Terminals VS - E2
Fully closed 200 - 600 ohms
Fully open 20 - 1,200 ohms
Terminals FC - E1
Fully closed No continuity
All other positions Continuity
Terminals VC - E2
Resistance value 200 - 400 ohms