Condenser HVAC: Service and Repair
REMOVAL
1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM
INSTALLATION HINT: Evacuate air from refrigeration system.
Charge system with refrigerant and inspect for leakage of refrigerant.
Specified amount:
850 ± 50 g (29.98 ± 1.76 oz.)
2. REMOVE THESE PARTS:
a. Hood lock brace
b. Center brace
3. DISCONNECT DISCHARGE HOSE AND LIQUID TUBE
Torque: 10 N.m (100 kgf.cm, 7 ft.lbf)
REMOVAL NOTE: Cap the open fittings immediately to keep moisture or dirt out of the system.
INSTALLATION HINT: Lubricate 2 new O-rings with compressor oil to compressor.
4. REMOVE CONDENSER
a. Remove 2 condenser mounting bolts.
b. Pull out the condenser between the radiator and the body.
INSTALLATION HINT: If condenser was replaced, add compressor oil to compressor.
Add 40 cc (1.4 ft.oz.)
Compressor oil:
ND-OIL 8 or equivalent
INSTALLATION
Installation is In the reverse order of removal.