Dome Lamp: Testing and Inspection
INSPECT ROOM LIGHT ASSEMBLY
a. Disconnect the connector from room light assembly.
b. Turn the room light switch ON, and check that there is continuity between terminal 2 and body ground.
c. Turn the room light switch DOOR, and check that there is continuity between terminal 1 and 2.
If operation is not as specified, replace the switch.