Removal and Installation
REMOVAL
1. REMOVE BATTERY AND BATTERY TRAY
2. DISCONNECT PS RESERVOIR
3. REMOVE DRIVE BELTS
a. Loosen the lock bolt, pivot bolt and adjusting bolt.
Torque:
Pivot bolt: 58 N.m (5g0 kgf.cm, 43 ft.lbf)
Lock bolt: 21 N.m (210 kgf.cm, 15 ft.lbf)
b. Remove the 2 drive belts.
4. REMOVE GENERATOR
a. Disconnect the generator connector.
b. Remove the rubber cap and nut, and disconnect the generator wire.
c. Disconnect the generator wire clamp from the generator.
d. Remove the lock bolt, bolt, nut and drive belt adjusting bar.
Torque: 21 N.m (210 kgf.cm, 15 ft.lbf)
e. Remove the pivot bolt and generator.
INSTALLATION
Installation is in the reverse order of removal.