Heated Oxygen Sensor
HEATED OXYGEN SENSORINSPECTION
1. INSPECT HEATED OXYGEN SENSOR
a. Bank 1 oxygen sensor No. 2
1. Using an ohmmeter, measure the resistance between the terminals.
If the resistance is not as specified, replace the sensor.
2. INSPECT HEATED OXYGEN SENSOR
a. Bank 2 oxygen sensor No. 2
1. Using an ohmmeter, measure the resistance between the terminals.
If the resistance is not as specified, replace the sensor.