Removal and Installation
REMOVAL1. REMOVE BATTERY
2. REMOVE BATTERY TRAY
3. REMOVE AIR CLEANER INLET NO.2
a. Disconnect the VSV connector.
b. Remove the 2 wire harness clamps.
c. Remove the vacuum hoses from the hose clamp.
d. Remove the 2 bolts, and then remove the air cleaner inlet No. 2.
4. REMOVE AIR CLEANER ASSEMBLY
a. Disconnect the mass air flow meter connector.
b. Disconnect the 4 vacuum hoses.
c. Loosen the 2 air cleaner cap bolts.
d. Loosen the air cleaner hose clamp bolt, and then remove the air cleaner cap.
e. Remove the air cleaner filter element.
f. Remove the wire harness from the 2 wire harness clamps.
g. Disconnect the vacuum hose.
h. Remove the 3 bolts, and then remove the air cleaner case.
5. REMOVE AIR CLEANER BRACKET
a. Remove the 2 bolts, and then remove the air cleaner bracket.
6. REMOVE AIR CLEANER INLET NO.1
a. Remove the bolt, and then remove the air cleaner inlet No. 1.
7. REMOVE STARTER ASSEMBLY
a. Disconnect the starter connector.
b. Open the terminal cap, remove the nut and disconnect the starter wire.
c. Remove the 2 bolts, and then remove the starter.
INSTALLATION
1. INSTALL STARTER ASSEMBLY
Torque:
Bolt 37 N.m (380 kgf.cm, 26 ft.lbf)
Nut 9.8 N.m (100 kgf.cm, 7 ft.lbf)
2. INSTALL AIR CLEANER INLET NO.1
Torque: 7.0 N.m (71 kgf.cm, 62 in.lbf)
3. INSTALL AIR CLEANER BRACKET
a. Install the air cleaner bracket with the 2 bolts. Using several steps, tighten the bolts uniformly in the sequence shown in the illustration.
Torque: 12 N.m (122 kgf.cm, 9 ft.lbf)
4. INSTALL AIR CLEANER ASSEMBLY
a. Install the air cleaner case to the air cleaner inlet No. 1 as shown in the illustration.
b. Using several steps, tighten the 3 bolts uniformly in the sequence shown in the illustration.
Torque: 5.0 N.m (51 kgf.cm, 44 in.lbf)
c. Connect the vacuum hose.
d. Install the 2 wire harness clamps.
e. Install the air cleaner filter element.
f. Connect the air cleaner hose No. 1 and tighten the air cleaner hose clamp bolt.
g. Tighten the 2 air cleaner cap bolts.
Torque: 5.0 N.m (51 kgf.cm, 44 in.lbf)
h. Connect the 4 vacuum hoses.
i. Connect the mass air flow meter connector.
5. INSTALL AIR CLEANER INLET NO.2
Torque: 7.0 N.m (71 kgf.cm, 62 in.lbf)
6. CHECK CONNECTION OF VACUUM HOSE
7. INSTALL BATTERY TRAY
8. INSTALL BATTERY
Torque:
Bolt and nut 5.5 N.m (56 kgf.cm, 49 in.lbf)
Terminal 3.5 N.m (36 kgf.cm, 31 in.lbf)