Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

Heated Oxygen Sensor

REMOVAL

CAUTION:
- Wear protective gloves when removing the sensor.
- The exhaust pipe assembly is extremely hot immediately after the engine has stopped.
- Confirm that the exhaust pipe assembly has cooled down before removing it.


1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.




2. REMOVE HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)
a. Disconnect the sensor connector.
b. Using SST, remove the sensor.
SST 09224-00010




3. REMOVE HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)
a. Disconnect the sensor connector.
b. Using SST, remove the sensor.
SST 09224-00010

INSTALLATION




1. INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)
a. Using SST, install the sensor.
SST 09224-00010

Torque:40 N.m (408 kgf.cm, 30 ft.lbf) for use with SST 44 N.m (449 kgf.cm, 32 ft.lbf) for use without SST

HINT: Use a torque wrench with a fulcrum length of 30 cm (11.81 in.).

b. Connect the sensor connector.




2. INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)
a. Using SST, install the sensor.
SST 09224-00010

Torque:40 N.m (408 kgf.cm, 30 ft.lbf) for use with SST 44 N.m (449 kgf.cm, 32 ft.lbf) for use without SST

HINT: Use a torque wrench with a fulcrum length of 30 cm (11.81 in.).

b. Connect the sensor connector.

3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

4. PERFORM INITIALIZATION
a. Perform initialization.

NOTE: Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.