Ambient Temperature Does Not Display
METER: METER / GAUGE SYSTEM: Ambient Temperature does not Display
Ambient Temperature does not Display
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. INSPECT THERMISTOR ASSEMBLY
(a) Remove cooler (ambient temp. sensor) thermistor.
(b) Measure resistance between terminals 1 and 2 of cooler (ambient temp. sensor) thermistor connector at each temperature.
HINT: As the temperature increases, the resistance decreases.
Standard resistance:
NG -- REPLACE THERMISTOR ASSEMBLY
OK -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE ACCESSORY METER ASSEMBLY