Installation
U151F AUTOMATIC TRANSAXLE: SPEED SENSOR: INSTALLATION
INSTALLATION
1. INSTALL SPEED SENSOR (NC SENSOR)
(a) Coat a new O-ring with ATF.
(b) Install the speed sensor with the bolt.
Torque: 11 Nm (115 kgf-cm, 8 ft-lbf)
HINT: Make sure to install the same manufacturer's sensor.
(c) Connect the speed sensor connector.
2. INSTALL SPEED SENSOR (NT SENSOR)
(a) Coat a new O-ring with ATF.
(b) Install the speed sensor with the bolt.
Torque: 11 Nm (115 kgf-cm, 8 ft-lbf)
HINT: Make sure to install the same manufacturer's sensor.
(c) Connect the speed sensor connector.
3. INSTALL AIR CLEANER BRACKET Installation
4. INSTALL AIR CLEANER CASE SUB-ASSEMBLY Installation
5. INSTALL AIR CLEANER CAP SUB-ASSEMBLY Installation
6. INSTALL BATTERY Installation
7. INSTALL CABLE TO NEGATIVE BATTERY TERMINAL
Some systems need initialization when disconnecting the cable from the negative battery terminal Repair Instruction - Initialization.