Air Inlet Damper Control Servo Motor Circuit - Air Conditioning System
AIR CONDITIONING: AIR CONDITIONING SYSTEM: B1442/42: Air Inlet Damper Control Servo Motor Circuit
B1442/42 - Air Inlet Damper Control Servo Motor Circuit
DESCRIPTION
The damper servo (air inlet control) sends pulse signals to inform the air conditioner amplifier of the damper position. The air conditioner amplifier activates the motor (normal, reverse) based on the signals to move the air inlet mode selection air inlet control damper to any position, which controls the intake air settings (FRESH, FRESH / RECIRCULATION and RECIRCULATION).
HINT
Confirm that no mechanical problem is present because this diagnostic code can be output when either a damper link or damper is mechanically locked.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. READ VALUE USING TECHSTREAM
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Select the items below in the Data List, and read the displays on the Techstream.
Data List / Air Conditioner
OK:
The display is as specified in the normal condition.
Result
C -- REPLACE AIR CONDITIONING AMPLIFIER
B -- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
A -- Continue to next step.
2. REPLACE AIR INLET CONTROL SERVO MOTOR
HINT
Since the servo motor cannot be inspected while it is removed from the vehicle, replace the servo motor with a normal one and check that the condition returns to normal.
OK:
Same problem does not occur.
NG -- REPLACE AIR CONDITIONING HARNESS
OK -- END