Installation
1UR-FE EMISSION CONTROL: AIR PUMP: INSTALLATION
1. INSTALL AIR PUMP ASSEMBLY
(a) Attach the 3 fittings of the air pump insulator to install the air pump to the bracket.
Text in Illustration
(b) Attach the 2 air pump connector clamps.
(c) Install the air pump with bracket with the 3 bolts.
Torque : 20 Nm (204 kgf-cm, 15 ft-lbf)
(d) Connect the air pump connector and attach the wire harness clamp.
2. CONNECT NO. 4 AIR INJECTION SYSTEM HOSE
(a) Connect the No. 4 air injection system hose so that its paint mark aligns with the rib of the air pump as shown in the illustration.
Text in Illustration
HINT
* Make sure the paint mark of the No. 4 air injection system hose is facing upward.
* Make sure the direction of the hose clamp is as shown in the illustration.
3. INSTALL UPPER RADIATOR SUPPORT SEAL Installation