A/T - Direct Clutch Failure/Excessive Case Bore Wear
TRANSMISSION: A4LDBULLETIN: # 060B
SUBJECT: No Reverse
APPLICATION: Ford
DATE: July 1991
No Reverse
Some A4LD valve body assemblies do not use a check ball to cushion reverse engagement. These valve bodies are equipped with a reverse engagement control valve. Inspect your valve body for the correct assembly using the 3 drawings provided. Do not leave out the check ball on valve bodies that do not have this valve. If the reverse engagement control valve is stuck you may have no reverse.
First Design
Second Design
Third Design
BULLETIN RECAP
^ If you have a reverse engagement control valve, leave the check ball out.
^ Inspect reverse engagement control valve for sticking.
FOR ADDITIONAL INFORMATION
TSB 89-14, 88-37, 88-35 & 86-59 and 1990 Seminar Manual