GC4 Component Check Actuate to Soft Position
GC4 COMPONENT CHECK ACTUATE TO SOFT POSITION^ Use a 12 volt power supply and connect negative lead to actuator Pin 4 and positive lead to Pin 3 for 1 to 2 seconds. This procedure should drive actuator to SOFT position. After this has been done remove power supply leads.
^ Using an analog ohmmeter. Measure resistance across actuator Pin 1 and Pin 2.
^ Ohmmeter reading is:
10,000 ohms or greater -- GO to GC5.
5 ohms or less -- GO to GC13.