Test W
PINPOINT TEST W: INSUFFICIENT AIR CONDITIONING (A/C) COOLINGTest W1:
Test W1-W3:
Test W4-W5:
Test W6-W7:
Normal Operation
Under normal operation, the Automatic Temperature Control (ATC) solenoid and manifold receives a ground from the Dual Automatic Temperature Control (DATC) module through circuit 1070 (BN/LB). When the heater control valve vacuum solenoid is to be energized, the ATC solenoid and manifold receives power from the DATC module through circuit 1069 (OG/LB).
Possible Causes
- An open or short to ground in circuit 1069 (OG/LB).
- ATC solenoid and manifold.
- DATC module.
- Heater control valve.
- Stuck or bound linkage or door.
- Leaking or plugged vacuum hose.