Test R
PINPOINT TEST R: THE PANEL/FLOOR CONTROL IS INOPERATIVE USING THE REAR AUXILIARY CLIMATE CONTROLSTest R1-R3:
Test R3-R5:
Normal Operation
Under normal operation, the auxiliary mode door actuator motor is driven to the floor position by supplying voltage to the front auxiliary mode control switch on circuit 1131 (LG) and ground to circuit 1124(WH).
The auxiliary mode door actuator motor is driven to the panel position by supplying voltage to the front auxiliary mode control switch on circuit 1124(WH) and ground to circuit 1131 (LG).
Possible Causes
- An open, short to voltage, ground or together in circuits 1124(WH) or 1131 (LG).
- Front auxiliary climate control assembly.
- Rear auxiliary climate control assembly.