Test N: The Temperature Control Is Inoperative/Does Not Operate Correctly - Manual Climate Control
PINPOINT TEST N: THE TEMPERATURE CONTROL IS INOPERATIVE/DOES NOT OPERATE CORRECTLY - MANUAL CLIMATE CONTROLN1:
N1-N3:
N3-N5:
N5-N7:
N7-N8:
Normal Operation
Under normal operation, the temperature blend door actuator is supplied voltage on circuit 295 (LB/PK) and ground on circuit 57 (BK). As the temperature selection changes it varies the voltage on circuit 437 (YE/LG) to the temperature blend door actuator. The temperature control potentiometer receives voltage through circuit 296 (WH/VT).
Possible Causes
- Fuse
- An open, short to voltage, ground or together in circuits 57 (BK), 295 (LB/PK), 296 (WH/VT) or 437 (YE/LG)
- Temperature blend door actuator
- Climate control switch
- Stuck or bound linkage or door