Operation CHARM: Car repair manuals for everyone.

Test F: An Individual Demand Lamp Is Inoperative

PINPOINT TEST F: AN INDIVIDUAL DEMAND LAMP IS INOPERATIVE

Normal Operation
The smart junction box (SJB) supplies voltage to the demand lamps on circuit CLN09 (YE/GN). The demand lamps are grounded through circuit GD139 (BK/YE). The glove compartment lamp (MKZ only) is case grounded.

This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Interior lamp


F1-F2: