Operation CHARM: Car repair manuals for everyone.

Air Cleaner Housing: Service and Repair




Air Cleaner Outlet Pipe

Removal and Installation

1. Disconnect the crankcase ventilation tube-to-Air Cleaner (ACL) outlet pipe quick connect coupling.

2. Release the clamp and disconnect the vacuum hose from the ACL (Air Cleaner) outlet pipe.

3. Loosen the ACL (Air Cleaner) outlet pipe-to-ACL (Air Cleaner) housing cover clamp.
- To install, tighten to 4 Nm (35 lb-in).


4. Loosen the ACL (Air Cleaner) outlet pipe-to-Throttle Body (TB) clamp.
- Remove the ACL (Air Cleaner) outlet pipe.

- To install, tighten to 4 Nm (35 lb-in).


5. NOTE: The ACL (Air Cleaner) outlet pipe should be securely sealed to prevent unmetered air from entering the engine.
To install, reverse the removal procedure.