Operation CHARM: Car repair manuals for everyone.

Ignition Cable: Testing and Inspection




1. Measure resistance of the high-tension leads.

Specifications: less than 22.9K Ohms per 1 m (3.28 ft)

2. If not as specified, replace the high-tension lead set.