Component Tests and General Diagnostics
KEYLESS CONTROL MODULE INSPECTION1. Remove the rear package trim (LH).
Terminal Voltage Table (Reference) - Connector View:
Terminal Voltage Table (Reference) - Pinouts (A - L):
Terminal Voltage Table (Reference) - Pinouts (M - P):
2. Measure the voltage at the keyless control module terminals as indicated.
3. Disconnect the keyless control module connector before inspecting for continuity at terminals C and L.
- If not as specified, inspect the parts listed under "Action" and the related wiring harnesses.
- If the parts and wiring harnesses are okay but the system still does not work properly, perform the keyless entry system problem check.