Operation CHARM
: Car repair manuals for everyone.
Home
>>
Mazda
>>
2001
>>
MPV LX V6-2.5L DOHC
>>
Repair and Diagnosis
>>
Powertrain Management
>>
Computers and Control Systems
>>
Oxygen Sensor
>>
Testing and Inspection
>>
Oscilloscope Patterns and Waveforms
Oscilloscope Patterns and Waveforms
Manufacturer Specific Pattern
HO2S signal (front, RH/LH)
-
PCM terminal: 60, 87 (+) <-> 91 (-)
-
Oscilloscope setting:
0.2 V
/DIV (Y),
200 ms
/DIV (X), DC range
-
Vehicle condition: Idle after warm up