Operation CHARM: Car repair manuals for everyone.

Oscilloscope Patterns and Waveforms

Manufacturer Specific Pattern

HO2S signal (front, RH/LH)




- PCM terminal: 60, 87 (+) <-> 91 (-)
- Oscilloscope setting: 0.2 V/DIV (Y), 200 ms/DIV (X), DC range
- Vehicle condition: Idle after warm up