Using SST (NGS Tester)
NOTE- PIDs for the following parts are not available on this model. Go to the appropriate part inspection.
- CMP sensor
- Main relay
1. Connect the NGS tester to the DLC-2.
2. Turn the ignition switch to ON.
3. Select the "PID/DATA MONITOR AND RECORD" function on the NGS display and press TRIGGER.
4. Select the appropriate PID on the NGS display and press START.
5. Measure the PID value.
- If PID value is not within the specification, follow the instructions in Action column.
NOTE
- Perform the SIMULATION TEST for the output device after PID/DATA measurement is completed.
- The simulation items that are used in the ENGINE CONTROL SYSTEM OPERATION INSPECTION are as follows.
- A/C RLY
- FAN 2
- FAN 3
- FP RLY
- IACV
- PRCV
- PRGV
- SEGRP
Part 1:
Part 2:
Part 3:
Part 4:
Part 5:
PID/DATA MONITOR table (Reference)
*1: Immobilizer system equipped
*2: Immobilizer system not equipped