Operation CHARM: Car repair manuals for everyone.

Pid/Data Monitor and Record Procedure

PID/Data Monitor and Record Procedure
1. Perform the NGS tester hook-up procedure.
2. Perform Steps 1 through 9 from the DTCs reading procedure.
3. Turn the ignition key to ON (engine off) or start the engine.





4. Move the cursor to PID/DATA MONITOR AND RECORD. Press the TRIGGER key to enter this selection.
5. Move the cursor to PIDs to view. Press the TRIGGER key. A star symbol will appear next to the item when it is selected.

Note:
- Press the TRIGGER key once again to deselect a PID.
- Press CLEAR to deselect all PIDs.





6. Press START to begin.
7. When ready to capture and store the selected PIDs, press the TRIGGER key.
8. Press the TRIGGER key again when ready to save information.





9. Move the cursor to STORE RECORDING AREA
1. Press the TRIGGER key.
10. Follow the instructions displayed on the SST (NGS tester) to save the recording data.