Operation CHARM: Car repair manuals for everyone.

Oscilloscope Patterns and Waveforms

Inspection Using An Oscilloscope (Reference)




SGC signal
- PCM terminal: 85 (+) - 86 (-)
- Oscilloscope setting: 0.5 V/DIV (Y), 10 ms/DIV (X), AC range
- Vehicle condition: idle after warm up