Operation CHARM: Car repair manuals for everyone.

Oscilloscope Patterns and Waveforms

Inspection Using An Oscilloscope (Reference)




NE signal
- PCM terminal: 21 (+) - 22 (-)
- Oscilloscope setting: 4 V/DIV (Y), 2.5 ms/DIV (X), AC range
- Vehicle condition: idle after warm up