Operation CHARM: Car repair manuals for everyone.

Generator Field Coil Signal

Inspection Using An Oscilloscope (Reference)




Generator field coil signal
- PCM terminal: 53 (+) - 103 (-)
- Oscilloscope setting: 0.5 V/DIV (Y), 1 ms/DIV (X), DC range
- Vehicle condition: idle after warm up