Operation CHARM: Car repair manuals for everyone.

Oscilloscope Patterns and Waveforms

Inspection Using An Oscilloscope (Reference)




SGC signal
- PCM terminal: 3V (+) <-> 4A (-)
- Oscilloscope setting: 2.0 V/DIV (Y), 20 ms/DIV (X), DC range
- Vehicle condition: Idling