Connectors

Connectors

Data link connector
Insert the probe into the service hole when connecting a jumper wire to the data link connector.

CAUTION: Inserting a jumper wire probe into the data link connector terminal may damage the terminal.




Disconnecting connectors
- When disconnecting two connectors, grasp the connectors, not the wires.




- Connectors can be disconnected by pressing or pulling the lock lever as shown.




Locking connector




When locking connectors, listen for a click indicating they are securely locked.

Inspection

When a tester is used for checking continuity or measuring voltage, insert the tester probe from the wiring harness side.




- Check the terminals of waterproof connectors from the connector side since they cannot be accessed from the wiring harness side






CAUTION: To prevent damage to the terminal, wrap a thin wire around the lead before inserting into terminal.