Programming and Relearning
BLIND SPOT MONITORING (BSM) CUSTOMIZED FUNCTION SETTING PROCEDURE
1. Connect the M-MDS to the DLC-2.
NOTE:
- The BSM can be customized using the IDS only.
2. After vehicle identification, the following can be selected from the IDS initialization screen.
- Select "Module Programming".
3. Then, select items from the screen menu in the following order.
- Select "Programmable Parameters".
- Select "Personality".
4. Select the item name, and than select either "Enabled/Disabled".
Items
- BSM buzzer