Variable Cam Sensor (VCT) Removal/Installation
-
VARIABLE CAM SENSOR (VCT) - 2.5L REMOVAL/INSTALLATION
Variable Camshaft Timing (VCT) Oil Control Solenoid - 2.5L
1. Remove the valve cover. See - Service and Repair.
2. Remove the bolt and the Variable Camshaft Timing (VCT) oil control solenoid.
- To install, tighten to 10 Nm {1.0 kgf-m, 89 in-lbf}.
3. To install, reverse the removal procedure.