CHECK VALVE (TWO-WAY) INSPECTION [WL-3]
id0116b5804800
1. Remove the check valve (two-way). (See FUEL TANK REMOVAL/INSTALLATION [WL-3].)
2. Inspect for airflow between A and B when vacuum is applied using a vacuum pump as shown in the figure.
Specification
Vacuum kPa {mmHg, inHg} |
Airflow |
|
---|---|---|
Port A
|
More than 18.6
{140, 5.50}
|
Yes
|
Port B
|
More than 4.9
{37, 1.5}
|
Yes
|
Except above
|
No
|
dbg116awb303
|