DIGITAL TRANSMISSION RANGE (TR) SENSOR REMOVAL/INSTALLATION [5R55S]


id0513c1254800

Caution
•  Water or foreign material entering the connector can cause poor connections or corrosion. Be sure that water or foreign material do not enter the connector when disconnecting it.

1.  Disconnect the negative battery cable.

2.  Remove the digital TR sensor insulator.

absggw00001811

3.  Disconnect the digital TR sensor connector.

absggw00001813

4.  Remove the selector cable.

5.  Set the adjustable wrench as shown in the figure to hold the manual shaft lever.

absggw00001032

6.  Remove the manual shaft nut.

7.  Remove the manual shaft lever.

8.  Remove the digital TR sensor.

absggw00001814

9.  Rotate the manual shaft to the torque converter housing side fully and return two notches to set the N position.

absggw00001034

10.  Install the digital TR sensor and loosely install the screws.

Caution
•  Tightening one screw before tightening the other may cause the digital TR sensor to bind or become damaged.
Note
•  The manual lever must be in the N position.

11.  Using the SST, align the digital TR sensor and tighten the screws in an alternating sequence.

absggw00001035

Tightening torque
6.5—9.5 N·m {67— 96 kgf·cm, 58—84 in·lbf}

Caution
•  Do not use an impact wrench. Hold the manual shaft lever when tightening the manual shaft nut, otherwise the transmission may be damaged.

12.  Install the manual shaft lever.

absggw00001032

Tightening torque
61—74 N·m {6.3— 7.5 kgf·m, 45—54 ft·lbf}

13.  Shift the selector lever to P position.

14.  Turn the manual shaft lever to P position.

15.  Install the selector cable.

absggw00001813

16.  Connect the digital TR sensor connector.

17.  Install the digital TR sensor insulator.

absggw00001811

Tightening torque
7.8—10.7 N·m {80—108 kgf·cm, 69.1—94.7 in·lbf}

18.  Connect the negative battery cable.

19.  Inspect digital TR sensor operation. (See DIGITAL TRANSMISSION RANGE (TR) SENSOR INSPECTION [5R55S].)